New voltage control and current control relays

The Finder 70 Series monitoring and control relay range has been extended with a new voltage control and new current control relay.

PRODUCT FOCUS

Monitoring relays such as these have the task of monitoring and signalling supply failures that could cause further machinery or system failure.

By informing the operator of abnormal conditions requiring immediate corrective action, damage to systems, machinery and equipment can be avoided or the possibility of machine downtime much reduced.

Type 70.61 - Voltage monitoring relay

Type 70.61 – phase failure and phase sequence control relay

This new product was specifically designed for the control of three-phase systems and motors, with particular reference to the control of compressors and pump control panels.

Featuring positive safety logic (the relay output contact opens in case of error detection) and Finder’s innovative European patent for its error detection principle, the 70.61 functions even under the condition of a regenerated phase.

Additional to the  phase failure and phase sequence functions other prime characterisitics include a single 6 A rated changeover output contact, suitability for 35mm rail mounting and a compact  width of 17.5mm.  Also available, as the 70.61-P000 version, it is equiped with push-in terminals.

Type 70.51 - Current monitoring relay

Type 70.51 – single phases current monitoring relay

The Type 70.51 current control relay will monitor a current value ​​in real time and will allow you to set, and it will signal, various critical “out of limits” conditions that might require an immediate response. Essential where safety, damage to equipment or down-time might result.

This device, with 1 x 10 A rated changeover output contact, has a wide supply voltage range of 24… 240 V AC/DC and six current control levels 0.1, 1, 2, 5, 10 and 16 A.

There are also 6 selectable functions, which include an under-current function, an over-current function and a window mode (over-current + under-current), either with or without trip memory feature.

Discover all the technical features of the Finder 70 Series relays in the dedicated datasheet.

RELATED PRODUCTS
70
SERIES
PREV
NEW TYPE 70.61 THREE-PHASE VOLTAGE MONITORING RELAY
NEXT
SELECTION GUIDE FOR THE FINDER 15 SERIES DIMMERS – WHICH DIMMER SHOULD YOU USE TO MEET YOUR NEEDS?
WHERE CAN I BUY FINDER PRODUCTS?

Find an authorized Finder dealer near you:

Loading...
DOWNLOAD THE FINDER APPS
Finder YOU
Finder Bliss
Finder Toolbox NFC
Explore Finder
© Copyright 2020 – FINDER S.p.A. sole proprietorship – All Rights Reserved – VAT number IT05732610018