Type 7P.01 - Surge Protection Device (SPD)

  • SPD suitable for low voltage systems for protection against overvoltages caused by direct discharges, induced and operating overvoltages
  • To be installed on the border between zones LPZ 0 and LPZ 1

Type 7P.02 - surge arrester (SPD)

  • Suitable for low voltage systems for protection against overvoltages caused by direct discharges, induced and operating overvoltages
  • Extremely low residual voltage

Type 7P.03 - Surge Protection Device (SPD) 7P

  • Suitable for low voltage systems for protection against overvoltages caused by direct discharges, induced and operating overvoltages
  • Replaceable varistor module

Type 7P.04 - Surge Protection Device (SPD)

  • SPD suitable for low voltage systems for protection against overvoltages caused by direct discharges, induced and operating overvoltages
  • To be installed on the border between zones LPZ 0 and LPZ 1

Type 7P.05 - Surge Protection Device (SPD)

  • Suitable for low voltage systems for protection against overvoltages caused by direct discharges, induced and operating overvoltages
  • Extremely low residual voltage

Type 7P.09 - Surge arrester

  • To be installed on the border between zones LPZ 0 and LPZ 1
  • Combination of high-performance varistors and gas spark gaps (GDT)

Type 7P.12 - Surge Protection Device (SPD)

  • SPD suitable for 230/400 V AC systems for protection against overvoltages caused by direct or indirect discharges
  • To be installed on the border between zones LPZ 0 and LPZ 1

Type 7P.13 - Surge Protection Device (SPD)

  • SPD suitable for 230/400 V AC systems for protection against overvoltages caused by direct or indirect discharges
  • To be installed on the border between zones LPZ 0 and LPZ 1

Type 7P.14 - Surge Protection Device (SPD)

  • SPD suitable for 230/400 V AC systems for protection against overvoltages caused by direct or indirect discharges
  • To be installed on the border between zones LPZ 0 and LPZ 1

Type 7P.15 - Surge Protection Device (SPD)

  • SPD suitable for 230/400 V AC systems for protection against overvoltages caused by direct or indirect discharges
  • To be installed on the border between zones LPZ 0 and LPZ 1

Type 7P.21 – Surge Protection Device (SPD)

  • Suitable for AC and DC systems/applications for protection against induced and switching overvoltages
  • Signaling with remote contact of the varistor status

Type 7P.22 - surge arrester (SPD)

  • Suitable for AC and DC systems/applications for protection against induced and switching overvoltages
  • To be installed on the border between zones LPZ 1 and LPZ 2

Type 7P.23 – Surge Protection Device (SPD)

  • Suitable for 230 V/400 V systems/applications for protection against induced and switching overvoltages
  • Visual indicator of the varistor status – functional/to be replaced

Type 7P.23.9 - Surge Protection Device (SPD)

  • Visual indicator of the varistor status - in the event of a fault
  • Signaling with remote contact of the varistor status in case of failure. Connector (07P.01) included in the package (depending on the version)

Type 7P.24 - surge arrester (SPD)

  • Suitable for 230 V/400 V systems/applications for protection against induced and switching overvoltages
  • To be installed on the border between zones LPZ 1 and LPZ 2

Type 7P.25 – Surge Protection Device (SPD)

  • Suitable for 230 V/400 V systems/applications for protection against induced and switching overvoltages
  • To be installed on the border between zones LPZ 1 and LPZ 2

Type 7P.26 – Surge Protection Device (SPD)

  • Visual indicator of the varistor status - in the event of a fault
  • Signaling with remote contact of the varistor status in case of failure. Connector (07P.01) included in the package (depending on the version)

Type 7P.26.9 - Surge Protection Device (SPD)

  • Visual indicator of the varistor status - in the event of a fault
  • Signaling with remote contact of the varistor status in case of failure. Connector (07P.01) included in the package (depending on the version)

Type 7P.27 – Surge Protection Device (SPD)

  • Suitable for AC and DC systems/applications for protection against induced and switching overvoltages
  • To be installed on the border between zones LPZ 1 and LPZ 2

Type 7P.31 - surge arrester (SPD)

  • Protects sensitive electrical and electronic devices from impulse overvoltages
  • 1 + 1 configuration between varistor and spark gap (without leakage current)

Type 7P.32 - surge arrester (SPD)

  • Protects sensitive electrical and electronic devices from impulse overvoltages
  • “1 + 1” configuration between varistor and spark gap (without leakage current), also designed for the protection of LED lamps

Type 7P.36 - Surge Protection Device (SPD)

  • Protects sensitive electrical and electronic devices from impulse overvoltages
  • Compliant with EN 61643-11: 2012

Type 7P.37 - surge arrester (SPD)

  • Protects sensitive electrical and electronic devices from impulse overvoltages
  • 1 + 1 configuration for a low Up value (residual voltage)

Type 7P.42 - surge arrester (SPD)

  • Suitable for AC systems/applications for protection against induced and switching overvoltages
  • To be installed on the border between zones LPZ 1 and LPZ 2

Type 7P.43 - surge arrester (SPD)

  • Suitable for AC systems/applications for protection against induced and switching overvoltages
  • To be installed on the border between zones LPZ 1 and LPZ 2

Type 7P.44 - surge arrester (SPD)

  • Suitable for AC systems/applications for protection against induced and switching overvoltages
  • To be installed on the border between zones LPZ 1 and LPZ 2

Type 7P.45 – Surge Protection Device (SPD)

  • Suitable for AC systems/applications for protection against induced and switching overvoltages
  • To be installed on the border between zones LPZ 1 and LPZ 2

Type 7P.62 - surge arrester (SPD)

  • Suitable for the protection of data lines and 2-wire telecommunication
  • Serial connection; optimizing the end of line protection from longitudinal (line-PG) and transverse (line-line) overvoltages

Type 7P.68 - Surge Protection Device (SPD)

  • Suitable for Ethernet lines with Cat 6 cabling, PoE (Power over Ethernet), and power lines data transmission up to 250 MHz
  • Protection for all pairs of conductors with D437attenuation
Type
Delete filters
Description
Language
Delete filters
Download
File type
CE
EurAsian Conformity (EAC)
VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung
Electrotechnical Testing Institute (EZU)
Industrial complete range
Industrial Apps

Industrial complete range

The range of Finder components and products for industry’s field include relays, timers and accessories for every kind of applications.

SHARE
RELATED SERIES
PRODUCTS

7S Series

Modular relays with forcibly guided contacts 6-10A

Configure products / 7P Series

Features

Reset
Type
0
Combined type 1 + 2 arresters
1
Type 1 surge arresters
2
Type 2 surge arresters
3
Type 3 surge arresters
Circuit
1
Single phase (1 varistor)
2
Single phase (1 varistor + 1 spark-gap)
3
Three-phase (3 varistors)
4
Three-phase (3 varistors + 1 spark-gap)
5
Three-phase (4 varistors)
6
2 varistor + 1 spark-gap
9
N-PE spark-gap
Supply version
8
AC (50/60 Hz)
9
DC (PV application)
1
N+PE connection
Supply voltage
000
1.000 V DC Max (or N+PE connection for spark gap modules)
700
700 V DC Max
420
420 V DC Max
275
275 V Max for SPD Type 1 “Low Up”, Type 2 (Uc) (for UN = 230-240 V AC) and Type 3
260
260 V Max (U ) for SPD Type 1+ 2 (for U = 230-240 V AC)
255
255 V Max (U ) for SPD Type 1, N+PE (7P.09)
Remote status signalling contact
0
Without remote status signalling contact
1
Built-in remote status signalling contact
2
Acoustic fault signalling
Nominal discharge current
100
100 kA (I imp Type 1)
012
12.5 kA (I imp Type 1)
020
20 kA (I n Type 2)
025
25 kA (I imp Type 1+2)
003
3 kA (In @ Uoc only for 7P.32)
  • 7P
  • -
  • -
  • -
  • -
  • -
  • -